Zopec Explore CPAP Backup & Travel Batteries
Runtime, device compatibility, cables, output specification and travel requirements vary by model and application.
Built-In UPS Function
Designed to monitor mains power and transition to reserve battery power during an outage.
Home and Travel Options
Choose between a higher-capacity AC-output model and a compact DC and USB-C model.
CPAP and Multipurpose Power
Suitable for selected CPAP configurations and everyday electronic equipment, subject to compatibility.
Australian Product Support
Product selection and purchasing assistance from OHM Medical IT.
Two portable-power solutions for different requirements
Zopec Explore 5500 CPAP Backup Battery | Australia
- 160 Wh battery capacity
- Built-in UPS and automatic switchover
- AC-output connection
- Fanless silent operation
- Home, road and backup applications
Zopec Explore Mini Battery System – 99.5 Wh Travel & CPAP Backup Battery
- 99.5 Wh battery capacity
- Automatic multi-voltage DC output
- 65 W USB-C capability
- Compact travel-focused design
- Fast recharge capability
More than a conventional portable power bank
Wall-Power Pass-Through
Power-Outage Detection
Automatic Battery Transition
This differs from a simple battery that must be manually connected after an outage and from a system that continually cycles its internal battery while connected to mains power.
The complete device, power connection and battery configuration should be tested before relying on the system for backup use.
Explore 5500 AC or Explore Mini DC?
| Zopec Explore 5500 AC | Zopec Explore Mini DC | |
|---|---|---|
| Primary positioning | Higher-capacity home UPS backup | Compact travel and portable power |
| Battery capacity | 160 Wh | 99.5 Wh |
| Output approach | AC-output connection — confirm Australian voltage and socket | Automatic multi-voltage DC and 65 W USB-C |
| UPS function | Built-in pass-through and automatic backup | Built-in pass-through and automatic backup |
| Manufacturer recharge guidance | Less than six hours | Less than 1.5 hours with an appropriate 65 W charging source |
| Approximate portability | Approximately 1.36 kg | Approximately 0.5 kg — confirm current model label |
| Typical application | Home CPAP backup, road travel and higher-capacity portable power | Travel CPAP, camping, compact backup and USB-C electronics |
| CPAP connection | AC connection, subject to Australian model specification | Correct model-specific DC cable or supported USB-C connection required |
| Air-travel consideration | 160 Wh — current airline approval and rules must be checked before travel | Under 100 Wh — carry-on and airline rules still apply |
| Recommended next step | Confirm Australian output and expected runtime | Confirm device model and required cable |
Zopec Explore 5500 AC
Zopec Explore Mini DC
Zopec Explore 5500 AC
- 160 Wh battery capacity
- Built-in wall-power pass-through
- Automatic transition to reserve battery power
- AC-output connection
- Fanless, silent cooling design
- Universal input charging capability
- Car-charging option
- Optional compatible solar charging
- Linkable battery capability where supported
Zopec Explore Mini DC
The Explore Mini DC combines a compact 99.5 Wh battery with automatic multi-voltage DC output, USB-C capability and built-in UPS functionality. It is designed for customers who prioritise compact size, fast charging and portable use.
- 99.5 Wh battery capacity
- Automatic multi-voltage DC output
- 65 W USB-C power capability
- Built-in UPS and automatic backup
- Fast recharge with an appropriate 65 W charger
- Compact and lightweight format
- Fanless silent operation
- Model-specific CPAP cable support
- Compatible solar-charging options where specified
Technical Specifications
Confirm the CPAP manufacturer, model, voltage and required cable before purchase.
Why CPAP battery runtime varies
CPAP without heated humidification
This generally provides the longest available battery runtime because the therapy device is the primary connected load.
CPAP with heated humidifier
Heating water uses additional energy and can materially reduce the available operating time.
CPAP with humidifier and heated tube
Using both heating systems creates the highest demand and usually produces the shortest operating time.
BiPAP or bilevel therapy
Bilevel devices may consume more energy because pressure changes throughout the breathing cycle.
Zopec's general runtime guidance indicates that humidifier use may reduce runtime by approximately 50–60%, while humidifier and heated-tube use together may reduce runtime by approximately 70–80%. Actual results vary by equipment and settings.
Information required for a runtime review:
- CPAP, APAP or BiPAP manufacturer
- Exact device model
- Therapy pressure
- Humidifier setting
- Heated-tube setting
- Required operating duration
- Battery model being considered
From home CPAP backup to portable everyday power
CPAP Power-Outage Backup
Maintain a connected backup-power option for selected home CPAP configurations.
CPAP Travel
Portable power for suitable CPAP machines during road trips, accommodation stays and other travel situations.
Camping and Caravanning
Battery power for suitable CPAP devices and smaller electronics when conventional mains power is unavailable.
Laptop and Tablet Power
Portable charging for compatible USB-C laptops, tablets and mobile devices.
Home Connectivity
Temporary power for selected internet modems, lights and small electronic equipment.
Emergency Preparedness
A portable reserve-power option for selected household electronics during temporary outages.
Confirm the equipment power requirement, output connection and expected operating time before use.
Check current airline requirements before travelling
Explore Mini DC — 99.5 Wh
Explore 5500 AC — 160 Wh
Before flying:
- Confirm the battery capacity shown on the product label
- Contact the airline before travel
- Carry the battery in cabin baggage
- Protect terminals and connections
- Keep the battery accessible
- Do not travel with a damaged, swollen or recalled battery
- Check rules for connecting or charging the battery onboard
Airline and international rules can change. Approval for one flight or airline does not guarantee approval for another.
How to select the right Zopec Explore battery
Identify the equipment
Confirm the connection
Review runtime requirements
Consider travel and charging
Choose Explore 5500 AC when:
- An AC-output connection is preferred
- Higher battery capacity is required
- Home power-outage backup is the primary application
- Portability is useful but smallest size is not the main priority
Choose Explore Mini DC when:
- Compact size and low weight are important
- The equipment has a supported DC cable
- USB-C charging is useful
- Travel and portability are the main priorities
Zopec Explore products supported by OHM Medical IT
OHM Medical IT supports Australian customers with Zopec product selection, device and cable review, quotations and after-sales assistance. Our wider biomedical engineering background helps us consider the complete equipment and power configuration rather than battery capacity alone.
Our Capabilities
- Explore 5500 and Explore Mini product advice
- CPAP manufacturer and model review
- Cable and accessory selection
- Runtime and configuration discussion
- Formal quotations and business purchasing
- Australian after-sales assistance
Include with your enquiry:
- Device manufacturer
- Device model
- Humidifier use
- Heated-tube use
- Expected operating duration
- Home, road, camping or air-travel application
- Preferred AC, DC or USB-C connection
Frequently asked questions about Zopec Explore batteries
-
Zopec Explore products are general-purpose portable batteries with built-in UPS functionality. They can support selected CPAP configurations and other compatible electronic equipment when the correct output, connection and power requirements have been confirmed.
-
The Explore 5500 AC provides higher battery capacity and an AC-output approach intended primarily for home backup and portable power. The Explore Mini DC is smaller and uses automatic multi-voltage DC and USB-C connectivity for travel-focused applications.
-
The Explore systems include pass-through and automatic-backup functionality. When correctly connected, they are designed to monitor incoming power and transition to reserve battery power if the external supply is interrupted.
-
Runtime depends on the battery model, CPAP model, therapy pressure, humidifier, heated tubing, bilevel operation, battery condition and environmental conditions. The actual configuration should be reviewed and tested.
-
The manufacturer provides runtime examples for selected CPAP and humidifier settings. Actual performance depends on the machine and settings. Heated tubing creates additional demand and can significantly reduce runtime.
-
The Explore Mini supports selected CPAP machines using the correct model-specific cable or approved connection. Confirm the Australian product bundle and exact CPAP model before purchasing.
-
Selected bilevel devices may be supported, but they can consume more energy than CPAP configurations. Confirm voltage, cable, output requirement and expected runtime before use.
-
The Explore Mini is rated below 100 Wh, but it must be carried and handled according to current airline and aviation requirements. Always check the airline's current policy before travel.
-
The Explore 5500 is rated at 160 Wh. Requirements for batteries in the 100–160 Wh range are stricter and may vary between airlines and jurisdictions. Obtain current written guidance from the airline before travelling.
-
Vehicle-charging options are available for selected Explore models. Use only the charger specified for the exact battery model and confirm the vehicle power source is suitable.
-
Compatible Zopec solar-charging options are available for selected battery models. Confirm the required panel, connection and expected charging conditions before purchase.
-
Choose according to your equipment, required connection, runtime objective, humidification settings, portability requirements and travel plans. OHM Medical IT can review this information and assist with model selection.
Not sure whether you need the Explore 5500 AC or Explore Mini DC?
Tell us your CPAP or electronic-device model, connection type, humidifier settings and required operating time. OHM Medical IT can help identify the most suitable battery and accessories.
Include the exact device manufacturer and model when contacting us.